Gel Documentation System

GELSTAN 1312 SERIES

Advanced Gel Documentation System for DNA, RNA, Protein Analysis and Routine Laboratory Imaging.

  • High Resolution Scientific Camera
  • UV / Blue Light Imaging
  • DNA & RNA Documentation
  • Advanced Analysis Software

Key Specifications

Camera TypeScientific Grade Camera
Imaging ModesUV / Visible Light
ApplicationsDNA, RNA, Protein
SoftwareImage Analysis Suite
ConnectivityUSB 2.0
Power Supply100 – 240V, 50/60Hz
CertificationCE Certified

Model Comparison

Parameters GELSTAN 1312 Star GELSTAN 1312+ GELSTAN 4X Advanced
Resolution 1.4 MP 1.4 MP 4.2 MP
Lens Manual Motorized Motorized
UV Transilluminator 302 nm 302 nm 302 nm
UV Filter 21 x 26 cm 21 x 26 cm 21 x 26 cm

Technical Specifications

Feature Description
Dark Hood Selection Flexibility to choose the dark hood configuration as per application requirements.
Universal Imager Designed as a universal imaging platform for diverse life science and research applications.
Scientific Grade Sensor Highly sensitive professional Scientific Grade Sony ICX205AL CCD sensor for superior image acquisition.
High Sensitivity Imaging Ideal imaging partner for sensitive and critical applications requiring exceptional signal detection.
Applications Suitable for fluorescence imaging, gene expression studies, protein expression studies, DNA/RNA assays, bacterial colonies, RFLP imaging, PCR detection, TLC imaging, 96-well plates, 2D gels, quantification and documentation.
Dye Compatibility Compatible with commonly used fluorescent dyes from Invitrogen, GE Life Sciences, Thermo Pierce, Sigma, Abcam, Bangalore Genei, Biobasic, and many others.
Advanced Imaging Applications Supports fluorescence assays, luminescence, colorimetric assays, bioluminescence, GFP imaging, and other applications requiring a high signal-to-noise ratio.
Custom Illumination Options Unlimited wavelength illumination options across the UV-Visible spectrum can be customized according to user requirements.
Research & Publication Ready Suitable for routine, critical, publication-quality imaging of DNA, RNA, proteins, biofluorescence, and multiplexing applications.
Image Colorization Monochrome gel images can be converted into multiple color scales corresponding to specific fluorescent dyes.
Dynamic Range Wide dynamic range of approximately 4.8 magnitudes, enabling detection of even faint bands with high accuracy.
Image Quality Produces high-definition images with excellent pixel density and sharp detail.
Camera Resolution Options Available in 1.4 MP, 3.2 MP, 4.2 MP, 5 MP, and 6 MP configurations for ultra-clear gel imaging.
Standard Resolution Available with 1.4 MP and 4.2 MP image resolution options.
CCD Sensor Sony ICX205AL scientific-grade CCD sensor.
Data Interface High-speed USB 2.0 / USB 3.0 interface for rapid data transfer from camera to PC. Optional FireWire interface available.
UV Safety System Dark hood equipped with UV safety switch that automatically turns off UV illumination when the hood is opened.
Auto UV Shut-Off Automatic UV shut-off feature activates after 45 seconds for enhanced user safety.
Filter System Integrated 3-position filter slider for flexible imaging applications.
Standard Filter Ethidium Bromide filter supplied as standard.
Epi Illumination Epi White illumination supplied as standard.
Software Package Includes powerful Gel-i image acquisition software and LabImage software for image capture, analysis, quantification, and reporting.

Accessories

Part Number Description
GA-01-14 Freeware 1D software for calculation of molecular weight, volume, dendogram, etc.
LAB300-14 Labimage 1D software version L300 (Licensed)
LAB320-14 Labimage ID software version L320 (Licensed)
LAB360-14 Labimage ID software version L360 (Licensed)
LENS-MA-MOTO-14 Lens upgrade from manual to motorized
LENS-MA-AUTO-14 Lens upgrade from manual to motorized with auto focus and numerical feedback to recall stored settings
GU-TW-01-14 Foldable trans white plate with evenly illuminated white light
GU-TUV-CO-306 UV transilluminator upgrade from 360 nm to 306 nm
GU-EUV-360 Epi UV attachment for 360 nm
GU-EUV-254 Epi UV attachment for 254 nm
GU-FL-20-21-14 Upgrade from 20 × 20 cm to 21 × 26 cm UV filter size
GU-TUV-BLUE-14 UV to Blue conversion screen for safe imaging of SYBR Green, SYBR Safe, GFP, Flamingo, and other blue wavelength excitable dyes
GU-KC-100 Kimberley Clark UV goggles
GU-EF-535-52 Emission filter of 535 nm with transmission range from 470–560 nm
GU-EF-460-52 Emission filter of 460 nm with transmission range from 430–490 nm
GU-EF-620-52 Emission filter of 620 nm with transmission range from 590–650 nm

Looking for the Right Imaging System for Your Lab?

Our technical experts will help you select the best system for your research needs.

Explore Related Products

1312 Chemi

Scientific-grade CCD imaging for chemiluminescence, fluorescence, and protein gels.

1012 Series

Professional quality images to suit for publication and routine imaging or diagnostic needs.

1312 Series

Dynamic range of the order of 3.0 Magnitude giving publication ready images

4X / 8X Chemi

Multicolor imaging for SYBR Green, SYBR Safe, GFP, Flamingo, EtBr and more fluorophores